35
Theoperatingvoltageisspeciedonthetypeplatelocatedinsidetheunit.
DANGER!
Neverusefusesthatdonotmatchtheabovespecicationsanddonotbypassblownfusesas
this could rise danger to persons or material assets
6. Reinstallthefuseholder,thepresstheholderdownuntilitproperlyengages.
7. Mount the terminal cover and tighten both mounting screws.
8. Insert and lock the water tank carriage (see chapter 5.1).
9. Reconnect the unit to the mains.
Replacing the ionizer electrodes
1. ShutdowntheDefensorPH28anddisconnecttheunitfromthemains(pullthemainsplugout
ofthesocket).
2. Remove the water tank carriage (see chapter 5.1) and tip the swivel plate up.
3. Replacetheionizerelectrodesaccordingtotheoppositegure.
4. Tip the swivel plate down.
5. Insert and lock the water tank carriage (see chapter 5.1).
6. Reconnect the unit to the mains.